Piezobalance Dust Monitor – 3520 Series

The ideal oil mist detection tool Piezobalance Dust Monitor – Model 3521 (10 μm & 4 μm) Standard contents: Main unit, operation manual, software, RS232C cable, AC adapter, NiMH battery pack, cleaning kit, PM10 and PM4 impactors, carrying case and calibration certificate. Piezobalance Dust Monitor – Model 3522 (2.5 μm) Standard contents: Main unit, operation manual, software, RS232C cable, AC adapter, NiMH battery pack, cleaning kit, PM2.5 impactor, carrying case and calibration certificate.
Download Technical Documents

Product Category:

Cleanroom & Environmental Test Instruments

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

Multi-line text content element

After binding data to rich-text content, the HTML content can be parsed.

  • Description

    High‑Performance Aerosol Monitoring with PIEZOBALANCE Technology 

    The Kanomax Piezobalance Dust Monitor Series 3521/3522 delivers next‑generation respirable aerosol measurement. Leveraging proprietary PIEZOBALANCE technology, these instruments directly read particulate mass concentration, distinguishing them from conventional particle‑counting dust monitors. The technology performs exceptionally well for oil mist and fine particulate tracking, serving as a critical instrument for environments demanding strict air purity.

    Precision Impactors for Target Particle Fractions 

    Fitted with precision impactors to match different monitoring objectives: Model 3521 comes with 4 μm and 10 μm impactors for larger particulate fractions; Model 3522 uses a 2.5 μm impactor optimized for fine aerosols. The impactor configuration isolates only the target particle sizes for analysis, improving data accuracy and applicability.

    Distinctive Gravimetric Sensing Principle 

    Instead of counting individual particles like standard dust meters, Kanomax Piezobalance units measure true particulate mass concentration. Incoming sample air first passes through an impactor to remove oversized particles. The remaining fine aerosols are electrically charged and deposited onto a piezo crystal. Mass buildup on the crystal shifts its resonant frequency, and this frequency change correlates directly with deposited particulate mass. This principle delivers highly reliable mass quantification for air quality control.

    Consistent, Trustworthy Measurement Performance 

    Built on this high‑precision sensing principle, the Piezobalance dust monitors generate stable, accurate results. Deriving particulate mass from piezo frequency variation delivers deeper analytical insight than traditional approaches. This precision is indispensable for applications with tight particulate limits, including pharmaceutical production, precision manufacturing and environmental compliance testing.

    Broad Industrial Use Cases 

    The Piezobalance Dust Monitor fits a wide array of industrial monitoring tasks. It excels at oil mist and aerosol surveillance in automotive fabrication, metal machining and chemical processing. Size‑selective sampling makes it a valuable asset for safeguarding occupational safety and satisfying air quality regulatory requirements.

    Occupational Health & Safety Focused Monitoring

    Kanomax Piezobalance Dust Monitors are essential to uphold rigorous indoor air quality standards and protect personnel. By supplying detailed, accurate mass concentration data, they support mitigation of hazardous aerosol exposure across industrial and field environments, helping create safer workspaces and strengthening air quality management.